New Features​

  • adds support for the artisan platform (Issue #231 and Issue #308)
  • adds support for the Coffee-Tech Engineering Silon ZR7
  • adds support for Has Garanti HGS and HSR series
  • adds support for Kaldi Fortis
  • adds support for Behmor 1kg
  • adds support for the VICTOR 86B Digital Multimeter (by Lewis Li)
  • adds support for Acaia coffee scales via directly Bluetooth Low Energy (BLE) communication without need for configuration or extra hardware (OS X only for now)
  • adds sorting of custom event buttons table by drag-and-drop (Issue 214, resolved by PR #345 contributed by Phil)
  • adds tick to swap Delta BT/ET LCDs and the corresponding curve z-order (Issue 330)
  • allows to set RoR smoothing for ET and BT separately
  • adds beep to playback aid and noisy text messages
  • adds Artisan Command actions to enable/disable AutoCHARGE and AutoDROP (autoCHARGE(<b>) and autoDROP(<b>))
  • adds Artisan Command tare(<n>) to tare channel <n> with 1 => ET, 2 => BT,.. (Issue 331)
  • renders values of background events in Combo mode (Issue 274)
  • adds background event marker and text settings to color configuration
  • adds translations for Farsi (thanks to Saeed Abdinasab)

Changes​

  • breaking feature: app domain changed to artisan-scope.org with the consequences that the app settings are now stored in a different location w.r.t. previous app versions
  • new app icon
  • new UI designs (buttons, LCDs,..)
  • curves are now drawn in LCD order thus ET is drawn above BT by default. If swap LCDs is ticked under Config >> Devices, also BT is drawn on top of ET.
  • hidden custom event button are interpreted as spacers to layout button groups
  • lib updates on all platforms but RPi (Python 3.7.3, Qt 5.12.3, PyQt 5.12.2, pymodbus 2.2, Matplotlib 3.1)
  • RESET button action disconnects serial, MODBUS and S7 connections
  • removes roasted weight, volume, density and moisture as well as colors from recent roast menu items
  • updated Chinese translations (thanks to Lewis Li)

Fixes​

  • fixes and error when starting designer (Issue 340)
  • adds back the missing ET RoR LCD (Issue 343)
  • fixes Update button in Roast Properties to harvest ambient sensors
  • improved Yoctopuce async mode (adds 1s* averaging on device mode)
  • fixes cross mouse rendering
  • keeps PhidgetManager running on "Keep ON"
  • improves the communication speed of several serial meters like the Voltcraft and Omega devices
  • fixes regression that could lead to a potential hang caused by slow communicating devices