Skip to main content

Kirsch & Mausser

Supporter
  • Producer: KIRSCH + MAUSER, Germany
  • Machines: UG15/UG22 retro, G45 retro, and G Series machines with networked PLC
  • Connection: Siemens S7 network via the network
  • Features:
    • logging of environmental temperature (ET), bean temperature (BT) and related rate-of-rise curves
    • logging of inlet temperature (IT), burner level, air flow, gas and drum pressure, and drum speed
    • on machines with PLC firmware version 2 or better all available actors like burner, drum speed, air flow, feeder, discharge/release doors, etc. can be controlled via sliders and buttons as well as automated actions (alarms, event replay, PID controller)
custom event buttons

Energy Ratings​

ModelSourceBurner (kW)Motor (kW)
UG 15LPG/NG554
UG 25LPG/NG804
G45LPG/NG14510
G60LPG/NG16013
G75LPG/NG20013
G90LPG/NG23015
G120LPG/NG28015